U-LINE OUTDOOR UOCP115 USER MANUAL & SERVICE MANUAL Pdf Download (2024)

U-LINE OUTDOOR UOCP115 USER MANUAL & SERVICE MANUAL Pdf Download (1)
  1. Manuals
  2. Brands
  3. U-Line Manuals
  4. Ice Maker
  5. UOCP115

U-LINE OUTDOOR UOCP115 USER MANUAL & SERVICE MANUAL Pdf Download (2)

15” clear ice maker

Hide thumbs Also See for Outdoor UOCP115:

  • (45 pages)
1
Table Of Contents 2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
44
45
46
47
48
49
  • Contents
  • Table of Contents
  • Troubleshooting
  • Bookmarks

Table of Contents

  • Table of Contents

  • Safety and Warning

  • Disposal and Recycling

  • Environmental Requirements

  • Electrical

  • Side by Side Installation

  • Water Hookup

  • Drain

  • Anti-Tip Bracket

  • General Installation

  • Grille Installation

  • Door Swing

  • Door Adjust

  • Cleaning

  • Cleaning Condenser

  • Ice

  • Troubleshooting

  • Wire Diagram

  • Product Liability

  • Warranty Claims

  • Parts

  • Ordering Replacement Parts

  • System Diagnosis Guide

  • Compressor Specifications

  • Troubleshooting Extended

  • Control Operation-Service

  • Thermistor

Advertisement

Quick Links

  • 1 Cleaning
  • Download this manual

USER GUIDE & SERVICE MANUAL

Outdoor Collection

UOCL115 / UOCP115

15" Clear Ice Maker

Table ofContents

NextPage
  • 1
  • 2
  • 3
  • 4
  • 5

Advertisement

Table of Contents

Troubleshooting

U-LINE OUTDOOR UOCP115 USER MANUAL & SERVICE MANUAL Pdf Download (3)

Related Manuals for U-Line Outdoor UOCP115

  • 15” clear ice maker, outdoor collection (45 pages)

  • Ice Maker U-Line BI2115 Specifications

    2000 series (2 pages)

  • 15” nugget ice machine (28 pages)

  • 15” nugget ice machine (54 pages)

  • 15” nugget ice machine (52 pages)

  • 15" crescent ice maker (46 pages)

  • Ice Maker U-Line UONP115SS01B Quick Start Manual

    (36 pages)

  • Ice Maker U-Line Outdoor Onb115 Quick Start Manual

    (34 pages)

  • (51 pages)

  • (47 pages)

  • (51 pages)

  • Ice Maker U-Line Ocl115 Quick Start Manual

    15“ clear ice machines (19 pages)

  • (53 pages)

  • (47 pages)

  • (47 pages)

  • (56 pages)

Summary of Contents for U-Line Outdoor UOCP115

  • Page 1 USER GUIDE & SERVICE MANUAL Outdoor Collection UOCL115 / UOCP115 15” Clear Ice Maker ● ●...
  • Page 2: Table Of Contents

    USER GUIDE & SERVICE MANUAL u-line.com Table of Contents Intro Wire Diagram Product Liability Safety Warranty Claims Safety and Warning Parts Disposal And Recycling Ordering Replacement Parts System Diagnosis Guide Installation Compressor Specifications Environmental Requirements Troubleshooting Extended Electrical Control Operation - Service Cutout &...
  • Page 3 ® to preserve the right product, in the right place, at the right temperature. Since 2014, U-Line has been part of the Middleby family of brands. All products are designed, engineered, and assembled in Milwaukee, Wisconsin, USA, and select products are available worldwide.
  • Page 4: Safety And Warning

    USER GUIDE u-line.com Safety and Warning WARNING NOTICE CALIFORNIA PROPOSITION 65 Please read all instructions before installing, This product contains chemicals known to the operating, or servicing the appliance. state of California to cause cancer and birth defects or other reproductive harm.
  • Page 5: Disposal And Recycling

    USER GUIDE u-line.com Disposal and Recycling DANGER RISK OF CHILD ENTRAPMENT. Before you throw away your old refrigerator or freezer, take off the doors and leave shelves in place so children may not easily climb inside. If the unit is being removed from service for disposal,...
  • Page 6: Environmental Requirements

    USER GUIDE u-line.com Environmental Requirements This unit is designed to operate between 50°F (10°C) and 100°F (38°C). Higher ambient temperatures may reduce the unit’s ability to reach low temperatures and/or reduce ice production on applicable models. For best performance, keep the unit out of direct sunlight and away from heat generating equipment.
  • Page 7: Electrical

    USER GUIDE u-line.com Electrical WARNING SHOCK HAZARD — Electrical Grounding Required. Never attempt to repair or perform maintenance on the unit until the electricity has been disconnected. Never remove the round grounding prong from the plug and never use a two-prong grounding adapter.
  • 14 15⁄16” (379 mm) PREPARE SITE Your U-Line product has been designed for either free- standing or built-in installation. When built-in, your unit does not require additional air space for top, sides, or rear. However, the front grille must NOT be obstructed, FRONT 28”...
  • Page 9: Side By Side Installation

    USER GUIDE u-line.com Side-by-Side Installation 3. Place bracket over holes and attach to unit with two screws removed in step 2 using a T-25 Torx driver. Two units may be installed side-by-side. Tighten screws fully. Cutout width for a side-by-side installation is the cutout 4.
  • Page 10: Water Hookup

    Plastic may crack compression fitting. or rupture with age and cause damage to your U-Line recommends using accessory water hookup kit - home. Part # 80-54674-00. The kit includes a 10’ (3 m) braided flexible water supply line and a brass hose fitting.
  • Page 11 USER GUIDE u-line.com 3. Locate water 8. Install retaining clip. valve in the front of the unit and thread water supply line through. NOTICE Route the water supply line through the unit so it does not come into contact with any internal components other than the solenoid valve.
  • Page 12: Drain

    DRAIN CONNECTION CAUTION With Trap and Vent Proper Drain If your U-Line unit did not come with a factory installed drain pump you must use a gravity A gravity drain may be used if: style drain connection. For assistance in Drain line has at least a 1”...
  • Page 13 Air Gap (Optional Hook-Up) requirements for a gravity drain, you may have ordered a pre-installed U-Line P60 drain pump. Waste If you need to install a P60 drain pump into your unit, see Shut-Off...
  • Page 14: Anti-Tip Bracket

    USER GUIDE u-line.com Anti-Tip Bracket Slide unit out so screws on top of unit are easily accessible. Remove the two screws from the opposite side of the hinge assembly using a T-25 Torx driver (see below). Place bracket over holes and attach to unit with two screws removed in step 2 using a T-25 Torx driver.
  • Page 15: General Installation

    USER GUIDE u-line.com General Installation INSTALLATION Plug in the power/electrical cord. LEVELING INFORMATION Gently push the unit into position. Be careful not Use a level to to entangle the cord or water and drain lines, if confirm the unit is applicable.
  • Page 16: Grille Installation

    USER GUIDE u-line.com Grille Installation REMOVING AND INSTALLING GRILLE WARNING Disconnect electric power to the unit before removing the grille. When using the unit, the grille must be installed. Removing the grille 1. Disconnect power to the unit. 2. Remove three screws (1).
  • Page 17: Door Swing

    USER GUIDE u-line.com Door Swing Wall 2-1/8" Min. (54 mm) 90° Door Swing Units have a zero clearance for the door to open 90°, when installed adjacent to cabinets. Stainless Steel models require 2-1/8" (54 mm) door clearance to accommodate the handle if installed next to a wall.
  • Page 18: Door Adjust

    USER GUIDE u-line.com Door Adjustments TO REVERSE THE DOOR HINGE COVER Hinge cover included with the literature bag is optional. To install hinge cover: Press hinge cover squarely over hinge. Hinge Cover Remove grille: Remove the grille (see GRILLE INSTALLATION section of this guide).
  • Page 19 USER GUIDE USER GUIDE u-line.com u-line.com Remove corresponding screws on opposite side of cabinet. On some models there may be a nut behind Remove door by tilting forward and lifting door off Install top hinge and door: Install slide spacers on opposite sidewalls: one or both screws on either side.
  • Page 20 (If the original adhesive no longer holds the gasket USER GUIDE in place, it may be necessary to apply a strip of u-line.com two-sided tape.) Install top hinge and door: Top Hinge...
  • Page 21 USER GUIDE u-line.com Control Operation CONTROL FUNCTION GUIDE FUNCTION COMMAND NOTES ON/OFF Press and release Unit will immediately turn On or OFF Adjust ice thickness See “Ice” section The o F / o C symbol will flash briefly after 5 seconds.
  • Page 22 USER GUIDE u-line.com Your clear ice machine is pre-set to produce ice between the optimal dimensions illustrated below: ICE CUBE THICKNESS ADJUSTMENT Cube Details NOTICE 1/4" TO 1/2" 1/16" TO 1/8" Ice thickness adjustment should only be made (6.4 mm to 12.7 mm) (1.6 mm to 3.2 mm)
  • Page 23 USER GUIDE u-line.com Airflow and Product Loading NOTICE The unit requires proper airflow to perform at its highest efficiency. Do not block the front grille at any time, or the unit will not perform as expected. Do not install the unit behind a door.
  • Page 24: Cleaning

    Do not use stainless steel cleaners or polishes on any glass surfaces. CLEAR ICE MACHINE CLEANING CYCLE Your U-Line clear ice machine has an automatic clean Clean any glass surfaces with a non-chlorine glass alert function. Cleaning cycles should be run as notified.
  • Page 25 Standpipe 6. Clean the Interior Bin as follows: U-Line Ice Machine Cleaner is used to remove lime scale and other mineral deposits. Refer to the following steps to initiate the self-cleaning cycle. • Dilute one packet of CLR cleaner into two quarts of water.
  • Page 26 Due to variations in water quality or inadequate maintenance your unit may become excessively coated in lime scale or calcium. U-Line offers a cost effective refresh kit which replaces many interior components and will return your unit to like new condition. Refresh kits may be ordered from your local distributor and installed by your local service company.
  • Page 27: Cleaning Condenser

    USER GUIDE USER GUIDE u-line.com u-line.com SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE Cleaning Condenser INTERVAL - EVERY SIX MONTHS To maintain operational efficiency, keep the front grille free of dust and lint, and clean the condenser when necessary.
  • Page 28 USER GUIDE u-line.com Extended Non-Use For questions regarding winterization, please call VACATION/HOLIDAY, PROLONGED SHUTDOWN U-Line at 414.354.0300. The following steps are recommended for periods of extended non-use: CAUTION Remove all consumable content from the unit. Damage caused by freezing temperatures is not covered by the warranty.
  • Page 29: Ice

    • Evaporator: Refrigerant flowing through an evaporator may sound like boiling liquid. BEFORE CALLING FOR SERVICE If you think your U-Line product is malfunctioning, read • Condenser Fan: Air moving through a condenser may the CONTROL OPERATION section to clearly understand be heard.
  • Page 30: Wire Diagram

    USER GUIDE u-line.com Wire Diagram Wire Diagram...
  • Page 31: Product Liability

    The part that caused the damage must be returned to U-Line in its entirety. The part must be clearly labeled with the serial number of the unit it was removed from, the date, and the servicer who removed the part.
  • Page 32: Warranty Claims

    Claims must be submitted online at • Final billing - Remodel www.U-LineService.com Warranty parts will be shipped at no charge after U-Line • 60 day submittal deadline from date of completed confirms warranty status. Please provide the model, serial service number, part number and part description.
  • Page 33: Parts

    USER GUIDE u-line.com Parts UOCL115-SS01A BACK PANEL 80-54335-00 BRAIDED WATER SUPPLY KIT ULAWATERHOOKUP BYPASS VALVE ASSEMBLY 80-55516-00 CIRCULATION PUMP 80-54137-00 CLEAR ICE MACHINE CLEANER ULACLRCLEAN COMPRESSOR 80-54140-00 COMPRESSOR ELECTRICALS 80-55202-00 CONDENSER ASSEMBLY 80-54293-00 CONDENSER FAN BLADE 80-54379-00 CONDENSER FAN MOTOR...
  • Page 34 USER GUIDE u-line.com Parts UOCP115-SS01A BACK PANEL 80-54335-00 BRAIDED WATER SUPPLY KIT ULAWATERHOOKUP BYPASS VALVE ASSEMBLY 80-55516-00 CIRCULATION PUMP 80-54137-00 CLEAR ICE MACHINE CLEANER ULACLRCLEAN COMPRESSOR 80-54140-00 COMPRESSOR ELECTRICALS 80-55202-00 CONDENSER ASSEMBLY 80-54293-00 CONDENSER FAN BLADE 80-54379-00 CONDENSER FAN MOTOR...
  • Page 35: Ordering Replacement Parts

    Warranty parts will be shipped at no charge after U-Line confirms warranty status. Please provide the model, serial number, part number and part description. Some parts will require color or voltage information.
  • Page 36: System Diagnosis Guide

    USER GUIDE u-line.com System Diagnosis Guide REGRIGERATION SYSTEM DIAGNOSIS GUIDE System Suction Suction Compressor Condenser Capillary Evaporator Wattage Condition Pressure Line Discharge Tube Normal Normal Slightly Very hot Very hot Warm Cold Normal below room temperature Overcharge Higher than Very cold...
  • Page 37: Compressor Specifications

    USER GUIDE USER GUIDE u-line.com u-line.com SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE Compressor Specifications DANGER OVERLOAD PROTECTOR Electrocution can cause death or serious injury. Burns from hot or cold surfaces can cause serious injury. Take precautions when servicing this unit.
  • Page 38: Troubleshooting Extended

    DC outputs located on the relay/power board. Included in this section are some diagnostic tips and of course, if additional help is required, please contact the U-Line Corp, “Customer Care Facility” at +1.414.354.0300 for assistance. NORMAL OPERATING SOUNDS All models incorporate rigid foam insulated cabinets to provide high thermal efficiency and maximum sound reduction for its internal working components.
  • Page 39 Go to component testing and turn on fill valve and verify 120V at the valve. Low Ice Dirty evaporator, dirty condenser, faulty Clean the evaporator using U-Line cleaner, clean the Production bin thermistor condenser coil if needed, check bin thermistor reading in service mode.
  • Page 40 USER GUIDE u-line.com Relay & DC Outputs PLUNGER SWITCH A plunger switch is used to monitor door state. When the One of the primary functions of the main control is to door is closed it comes into contact with the plunger which operate the multiple relay and DC outputs during each closes a circuit which turns the light and display off.
  • Page 41 If TDS is acceptable, unit must be cleaned and APPENDIX any leakage addressed with a seal kit. (U-Line E11: Sensor in base near fan detecting water service part # 80-55371-13) This sensor is designed to detect water escaping the Area in Front of Sensors (Condenser Side) is Wet product due to any type of malfunction inside the machine.
  • Page 42 USER GUIDE u-line.com If unit fills, the float switch is malfunctioning and d. Check compressor operation. needs to be replaced (part # 80-55538-00). • If unit is not cooling or compressor is not If unit is 3 Class product, enter service mode and operating, diagnose and fix system problem.
  • Page 43: Control Operation-Service

    USER GUIDE u-line.com Control Operation-Service CONTROL FUNCTION GUIDE FUNCTION COMMAND DISPLAY/OPTIONS UI BUTTON LAYOUT and release Unit will immediately Press ON/OFF turn ON or OFF Sabbath Mode See “Sabbath Mode” section Silent Mode (ice production Display will shw “3H” Hold...
  • Page 44 USER GUIDE u-line.com SERVICE MODE GUIDE SERVICE MODE GUIDE 0. Exit THERMISTOR 1 - BIN 1. Thermistor 1 temperature not including offsets. This shows the pure thermistor reading with no off- 2. Thermistor 2 temperature not including offsets. sets taken into account.
  • Page 45 USER GUIDE u-line.com 15. CLEAR ERROR LOG To clear errors, press and hold (5 seconds) when CLR is flashing. 16. THERMISTOR - 1 DIFFERENTIAL This number should not be adjusted 17. Does not apply to this model 18. Does not apply to this model 19.
  • Page 46 MODEL NUMBER 1. Disconnect the unit from power source. 2. Push and hold the U-Line button. 3. While still holding the U-Line button, plug the unit into the appropriate power source. 4. When the flashing digits appear (3-5 seconds), use the up and down arrow buttons to select the appropriate model number*.
  • Page 47 USER GUIDE u-line.com Control Operation-Service...
  • Page 48: Thermistor

    USER GUIDE u-line.com Thermistor Thermistor Resistance Data Nominal Resistance Thermistors are used for various temperature readings. Temp (F) Temp (C) (OHMS)* Thermistors provide reliable temperature readings using a 169157 resistance which varies based on surrounding temperatures. 121795 If a faulty thermistor is suspected, it may be tested using 88766 an accurate ohmmeter.
  • Page 49 For products installed and used for normal residential use, material cosmetic defects are included in this warranty, with coverage limited to 60 days from the date of original purchase. All service provided by U-Line under the above warranty must be performed by a U-Line factory authorized servicer, unless otherwise specified by U-Line.

This manual is also suitable for:

Outdoor uocl115Outdoor uocp115ss01aOutdoor uocl115ss01a

U-LINE OUTDOOR UOCP115 USER MANUAL & SERVICE MANUAL Pdf Download (2024)

References

Top Articles
Latest Posts
Recommended Articles
Article information

Author: Rob Wisoky

Last Updated:

Views: 6492

Rating: 4.8 / 5 (48 voted)

Reviews: 95% of readers found this page helpful

Author information

Name: Rob Wisoky

Birthday: 1994-09-30

Address: 5789 Michel Vista, West Domenic, OR 80464-9452

Phone: +97313824072371

Job: Education Orchestrator

Hobby: Lockpicking, Crocheting, Baton twirling, Video gaming, Jogging, Whittling, Model building

Introduction: My name is Rob Wisoky, I am a smiling, helpful, encouraging, zealous, energetic, faithful, fantastic person who loves writing and wants to share my knowledge and understanding with you.